Installation method of compressed air filter

Model No. : YF-B090

Brand : YUKA

Material : Aluminum Alloy

Housing Serve Lige : 15 Years

Element Serve Life : 6000~8000 Hours

Maxi. Operate Pressure : 1.6 Mpa

Operate Temperature : 1.5~80ºc

Connection : Rc2"

Filtration Performance : From 5 μm To 0.01μm

Resistance Corrosion : Inside And Outside

Filter Type : Coalescing

Option Parts : Connection Kit

Configuration : Manual Ball Valve

Element Top Cap : Diversion Fin Less Pressure Loss

Element Top Cap Color : Colorful To Distinguish

Color : Light Blue

Transport Package : Brown Inner Box & Cardboard

Specification: Dimension : 174 X 142x 558mm

HS Code : 8421399090

Clapboard : Without Clapboard

Filter Number : 1

Medium Material : Fiberglass

Filtration Grade : Medium Filter

Type : Cartridge Filter

Efficiency : F9

Flow Rate : 10 M³/Min

Place of Origin : China

Brand Name : Yuka

Price : Negotiable

Packaging Details : Box Package

Delivery Time : 3-7working days

Payment Terms : L/C,T/T

MOQ : 50pcs

Supply Ability : 300,000pcs/month

Contact Now

Product Description

Installation method of Compressed Air Filter

①Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.

②The Filter Element should be replaced regularly. When replacing the filter element, use an Allen wrench to unscrew the four screws of the lower cover and take out the old filter element from below. Carefully record the replacement time. It is recommended that the working time z should not exceed 8000 hours.

③The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;

④Different grades of compressed Air Filters can be equipped with electronic drain valves or manual valves according to customer requirements.

7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR
PF AO AA AX ACS AR AAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) Dust particles whose diameter more than 1μm can be removed Dust particles whose diameter more than 0.01μm can be removed

International test and measurement standard ISO12500
>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.

Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.

Filtration Grade PF AO AA AX ACS AR AAR
Size of solid particles(ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm
Filtration performance of solid particles(ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+%
Filtration performance of oil(ISO12500-1) 50% 80+% 99.9+% 99.99+% - - -
Residual oil content(ISO12500-1) 5mg/m³ 0.6mg/m³ <0.01mg/m³ <0.001mg/m³ <0.004mg/m³ - -

Product Picture

Installation method of compressed air filterInstallation method of compressed air filter


Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).For application in other working pressure, please refer to the correction factors.

Model Pipe size Flow rates Dimension (mm)
L/S m³/min scfm W(Width) D(Depth) H (Height) A B C(clearance for housing)
YFB010 RC1/2" 16.7 1.0 35.5 96 79 252 29 223 118
YFB020 RC3/4" 25.0 1.5 53.0 96 79 252 29 223 118
YFB030 RC3/4" 30.0 1.8 63.6 96 79 286 29 257 153
YFB040 RC1" 33.3 2.0 71.0 96 79 286 29 257 153
YFB060 RC1" 60.0 3.6 127.0 138 111 357 37 320 208
YFB070 RC1" 83.3 5.0 177.0 138 111 458 37 421 303
YFB080 RC1-1/2" 125.0 7.5 265.0 138 111 458 37 421 303
YFB090 RC2" 166.7 10.0 353.1 174 142 558 58 500 467
YFB100 RC2-1/2" 216.7 13.0 459.0 174 142 558 58 500 467
YFB110 RC2" 283.3 17.0 600.0 174 142 838 58 780 794
YFB120 RC2-1/2" 316.7 19.0 671.0 174 142 838 58 780 794
YFB130 RC3" 416.7 25.0 883.0 220 184 645 74 571 514
YFB140 RC4" 466.7 28.0 989.0 220 184 645 74 571 514
YFB150 RC3" 683.3 41.0 1448.0 220 184 902 74 828 764
YFB160 RC4" 800.0 48.0 1695.0 220 184 902 74 828 764
Technical requirements Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C

Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

Installation method of compressed air filterInstallation method of compressed air filter




YUKA Package
Installation method of compressed air filter


YUKA service
a. Providing professional consultation, technical support and special solutions
b. Providing timely feedback on complaints
c. Providing perfect after sales service and warranty

Q:Why choose us?
a. Over 20 years' practical experiences in R&D and manufacturing Compressed air treatment;
b. Founder of Compressed Air Nation Standard GB/T30475.1-2013 and GB/T30475.2-2013;
c. ISO 9001:2015, CE and product follow ISO8573-1;
d. With Germany Imported high efficiency filtration Test Instrument;
e.All goods had been 100% test before dispatched.


FAQ
Q1. What kind of your company is it?
We're the manufacturer integrated with R&D, production and sales.

Q2. How about your technical conditions and production capability?
Complete process documents and equipment, mass production.

Q3. What is the delivery time?
Delivery time depends on the order quantity, normally is 3-5 working days after 30% payment.

Q4. Do you have a warranty?
Yes, for filter, it is 1 year normally.

Q5. Can you supply customized product?
Yes, we have a professional technical team to provide you with the best solution and complete production processes and control to provide you with satisfied product.


China Installation method of compressed air filter wholesale

Installation method of compressed air filter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hongrijia Depurate Facility Science & Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)